CyberzSOC

Publication detail
← Back to advisories & guidance

ICSA-24-135-04: Mitsubishi Electric Multiple FA Engineering Software Products (Update G) ↗ source

May 14, 2024 CISA ICS Advisory

Summary

Multiple Vulnerabilities due to vulnerabilities in Jungo's WinDriver in multiple FA engineering software products. Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition and/or to gain Windows system privileges and execute arbitrary commands. CVE-2023-51776: A privilege escalation vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to escalate Windows system privileges and execute arbitrary commands. CVE-2023-51777: A denial-of-service vulnerability due to uncontrolled resource consumption caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CVE-2023-51778: A denial-of-service vulnerability due to an out-of-bounds write caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products.

Advisory Details CISA ICS CSAF feed

Advisory ID
ICSA-24-135-04
Status
Final · version 15
Initial release
2024-05-14
Last revised
2026-09-01 (15 revisions)
Vendor
Mitsubishi Electric; Mitsubishi Electric Iconics Digital Solutions
Critical infrastructure sectors
Critical Manufacturing
Deployed
Worldwide
Vendor headquarters
Japan

Republished vendor advisory. This ICSA is a verbatim republication of Mitsubishi Electric 2024-001 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does…

Credit: Jongseong Kim, Byunghyun Kang, Sangjun Park, Yunjin Park, Kwon Yul, Seungchan Kim (today-0day, BoB 12th)

Affected products (40)
  • Mitsubishi Electric CPU Module Logging Configuration Tool — <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) — <=2.5
  • Mitsubishi Electric CW Configurator — <=1.019V
  • Mitsubishi Electric Data Transfer — <=3.58L
  • Mitsubishi Electric Data Transfer Classic — <=1.00A
  • Mitsubishi Electric EZSocket — <=5.92
  • Mitsubishi Electric FR Configurator SW3 — all versions
  • Mitsubishi Electric FR Configurator2 — <=1.32J
  • Mitsubishi Electric GENESIS64 — >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) — <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) — <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 — <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 — <=1.315D
  • Mitsubishi Electric GX Developer — all versions
  • Mitsubishi Electric GX LogViewer — <=1.154L
  • Mitsubishi Electric GX Works2 — <=1.622Y
  • Mitsubishi Electric GX Works3 — <=1.106L
  • Mitsubishi Electric iQ Works (MELSOFT Navigator) — <=2.102G
  • Mitsubishi Electric MI Configurator — all versions
  • Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224) — <=A8
  • Mitsubishi Electric MR Configurator (SETUP221) — all versions
  • Mitsubishi Electric MR Configurator2 — <=1.150G
  • Mitsubishi Electric Position Board Utility2 (MRZJW3-MC2-UTL) — <=3.40
  • Mitsubishi Electric MX Component — <=5.007H
  • Mitsubishi Electric MX OPC Server DA/UA (Software packaged with MC Works64) — all versions
  • Mitsubishi Electric PX Developer/Monitor Tool — <=1.58L
  • Mitsubishi Electric RT ToolBox3 — <=2.20W
  • Mitsubishi Electric RT VisualBox — <=1.11M
  • Mitsubishi Electric Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) — <=4.14Q
  • Mitsubishi Electric MELSECNET/H Interface Board software package (SW0DNC-MNETH-B) — <=36N
  • Mitsubishi Electric CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B) — <=1.25B
  • Mitsubishi Electric CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J) — <=1.18U
  • Mitsubishi Electric CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B) — <=1.31H
  • Mitsubishi Electric C Controller Interface Module utility (SW1DNC-QSCCF-B) — <=2.10
  • Mitsubishi Electric MELSOFT EM Software Development Kit (SW1DND-EMSDK-B) — <=1.020W
  • Mitsubishi Electric MT Works2 — <=1.200J
  • Mitsubishi Electric ICONICS Suite — >=10.97.1|<=10.97.3
  • Mitsubishi Electric CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B) — <=1.18U
  • Mitsubishi Electric Iconics Digital Solutions GENESIS64 — >=10.97.1|<=10.97.3
  • Mitsubishi Electric Iconics Digital Solutions ICONICS Suite — >=10.97.1|<=10.97.3
Revision history (15)
  • 2026-09-01 — v15: CISA Republication update based on Mitsubishi Electric 2024-001 advisory
  • 2026-09-01 — v14: Updated the affected versions for GENESIS64 and ICONICS Suite. Added GENESIS64 and ICONICS Suite as updated products. Added a workaround for GENESIS64 and ICONICS Suite.
  • 2026-06-09 — v13: CISA Republication update based on Mitsubishi Electric 2024-001 advisory
  • 2026-01-15 — v12: CISA Republication - Update E - Added version information to affected product and mitigation sections.
  • 2026-01-15 — v11: Added ICONICS Suite and MT Works2 to the "Affected Products" section. And added the updated products such as GENESIS, Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224), PX Developer/Monitor Tool, RT VisualBox, C Controller Interface Module utility (SW1DNC-QSCCF-B), and…
  • 2025-08-28 — v10: CISA Republication - Update D - Added version information to affected product and mitigation sections.
  • 2025-08-28 — v9: Added the updated products such as CW Configurator, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU), and MELSOFT EM Software Development Kit (SW1DND-EMSDK-B) to the "Countermeasures for Products" section.
  • 2025-05-15 — v8: CISA Republication - Update C - Added version information for Position Board Utility2
  • 2025-05-15 — v7: Added products for which there are no plans for release fixed versions to the "Countermeasures for Customers" section. And added Position Board Utility2 (MRZJW3-MC2-UTL) to the "Countermeasures for Products" section as a updated product.
  • 2025-01-30 — v6: Added guidance for products that do not provide downloadable updates to the "Countermeasures for Customers" section. And added the updated products such as CPU Module Logging Configuration Tool, CSGL (GX Works2 connection configuration), EZSocket, FR Configurator2, GX LogViewer, GX Works2, GX…
  • 2025-01-30 — v5: CISA Republication - Update B - Added version information to affected product and mitigation sections.
  • 2024-10-31 — v4: CISA Republication - Update A - Added version information to affected product and mitigation sections.
  • 2024-10-31 — v3: In the "Affected Products" section, the product names of Position Board Utility2 (MRZJW3-MC2-UTL), MELSECNET/H Interface Board software package (SW0DNC-MNETH-B), CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B), CC-Link IE Field Network Interface Board software package…
  • 2024-05-14 — v2: CISA Republication - Initial Republication of Mitsubishi Electric 2024-001
  • 2024-05-14 — v1: Initial Publication

From CISA's machine-readable CSAF 2.0 advisory (JSON).

Vulnerabilities as Stated by the Advisory

CVEWeaknessCVSS v3Details
CVE-2024-22106 CWE-269 Improper Privilege Management 6.0 Medium A privilege escalation and denial-of-service vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition and/or to escalate Windows system privileges and execute arbitrary commands. CISA SSVC — Exploitation: None · Automatable: No · Impact: Total

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2023-51776 CWE-269 Improper Privilege Management 4.4 Medium A privilege escalation vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to escalate Windows system privileges and execute arbitrary commands. CISA SSVC — Exploitation: None · Automatable: No · Impact: Total

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2023-51777 CWE-400 Uncontrolled Resource Consumption 4.4 Medium A denial-of-service vulnerability due to uncontrolled resource consumption caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2023-51778 CWE-787 Out-of-bounds Write 4.4 Medium A denial-of-service vulnerability due to an out-of-bounds write caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-22102 CWE-400 Uncontrolled Resource Consumption 4.4 Medium A denial-of-service vulnerability due to uncontrolled resource consumption caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-22103 CWE-787 Out-of-bounds Write 4.4 Medium A denial-of-service vulnerability due to an out-of-bounds write caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-22104 CWE-787 Out-of-bounds Write 4.4 Medium A denial-of-service vulnerability due to an out-of-bounds write caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-22105 CWE-400 Uncontrolled Resource Consumption 4.4 Medium A denial-of-service vulnerability due to uncontrolled resource consumption caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-25086 CWE-269 Improper Privilege Management 4.4 Medium A privilege escalation vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to escalate Windows system privileges and execute arbitrary commands. CISA SSVC — Exploitation: None · Automatable: No · Impact: Total

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-25087 CWE-400 Uncontrolled Resource Consumption 4.4 Medium A denial-of-service vulnerability due to uncontrolled resource consumption caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition. CISA SSVC — Exploitation: None · Automatable: No · Impact: Partial

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-25088 CWE-269 Improper Privilege Management 4.4 Medium A privilege escalation vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to escalate Windows system privileges and execute arbitrary commands. CISA SSVC — Exploitation: None · Automatable: No · Impact: Total

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

CVE-2024-26314 CWE-269 Improper Privilege Management 4.4 Medium A privilege escalation vulnerability due to improper privilege management caused by a vulnerability in Jungo's WinDriver exists in multiple FA engineering software products. If a malicious code is executed on a computer where the affected software product is installed, this vulnerability may allow a local attacker to escalate Windows system privileges and execute arbitrary commands. CISA SSVC — Exploitation: None · Automatable: No · Impact: Total

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for CPU Module Logging Configuration Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed ve… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 2.6 or later for CSGL (GX Works2 connection configuration). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fi… ↗

Vendor fix: Mitsubishi Electric is releasing fixed version 1.020W or later for CW Configurator. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mi… ↗

Affected, fixed & timeline

Affected:

  • Mitsubishi Electric CPU Module Logging Configuration Tool <=1.154L
  • Mitsubishi Electric CSGL (GX Works2 connection configuration) <=2.5
  • Mitsubishi Electric CW Configurator <=1.019V
  • Mitsubishi Electric Data Transfer <=3.58L
  • Mitsubishi Electric Data Transfer Classic <=1.00A
  • Mitsubishi Electric EZSocket <=5.92
  • Mitsubishi Electric FR Configurator SW3 all versions
  • Mitsubishi Electric FR Configurator2 <=1.32J
  • Mitsubishi Electric GENESIS64 >=10.97.1|<=10.97.3
  • Mitsubishi Electric GT Designer3 Version1 (GOT1000) <=1.310Y
  • Mitsubishi Electric GT Designer3 Version1 (GOT2000) <=1.317F
  • Mitsubishi Electric GT SoftGOT1000 Version3 <=3.310Y
  • Mitsubishi Electric GT SoftGOT2000 Version1 <=1.315D
  • Mitsubishi Electric GX Developer all versions
  • Mitsubishi Electric GX LogViewer <=1.154L
  • … and 25 more

Vendor fix: Mitsubishi Electric is releasing fixed version 3.59M or later for Data Transfer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.01B or later for Data Transfer Classic. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 5.A or later for EZSocket. Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.33K or later for FR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For more info…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.315D or later for GT Designer3 Version1 (GOT1000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT Designer3 Version1 (GOT2000). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.315D or later for GT SoftGOT1000 Version3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.320J or later for GT SoftGOT2000 Version1. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.160S or later for GX LogViewer. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.625B or later for GX Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.110Q or later for GX Works3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.106L or later for iQ Works (MELSOFT Navigator). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version A9 or later for Mitsubishi Electric Numerical Control Device Communication Software (FCSB1224). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.155M or later for MR Configurator2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 3.50 or later for Position Board Utility2 (MRZJW3-MC2-UTL). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.p…

Vendor fix: Mitsubishi Electric is releasing fixed version 5.008J or later for MX Component. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.59M or later for PX Developer/Monitor Tool. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 2.50C or later for RT ToolBox3. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 1.12N or later for RT VisualBox. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 4.15R or later for Setting/monitoring tools for the C Controller module (SW4PVC-CCPU). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerabi…

Vendor fix: Mitsubishi Electric is releasing fixed version 37P or later for MELSECNET/H Interface Board software package (SW0DNC-MNETH-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pd…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.26C or later for CC-Link System Master/Local Interface Board software package (SW1DNC-CCBD2-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psir…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-J). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.32J or later for CC-Link IE Controller Network Interface Board software package (SW1DNC-MNETG-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/ps…

Vendor fix: Mitsubishi Electric is releasing fixed version 2.20 or later for C Controller Interface Module utility (SW1DNC-QSCCF-B). Mitsubishi Electric does not provide downloadable updates for the product. Contact your place of purchase for assistance. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.025B or later for MELSOFT EM Software Development Kit (SW1DND-EMSDK-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.205P or later for MT Works2. Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf".

Vendor fix: Mitsubishi Electric is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to this vulnerability. For m…

Vendor fix: Mitsubishi Electric is releasing fixed version 1.19V or later for CC-Link IE Field Network Interface Board software package (SW1DNC-CCIEF-B). Download the fixed version from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/v…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for GENESIS64, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of GENESIS64 consider replacing it with the successor product GENESIS which is not vulnerable to this vu…

Vendor fix: Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.98 or later for ICONICS Suite, download the fixed version from the link "https://iconicsinc.my.site.com/community/s/resource-center/product-downloads" and install it. As an alternative, Mitsubishi Electric recommends users of ICONICS Suite consider replacing it with the successor product GENESIS which is not vulnerable to…

No fix planned: There are no plans to release fixed version for FR Configurator SW3, GX Developer, MI Configurator, MR Configurator (SETUP221), and MX OPC Server DA/UA (Software packaged with MC Works64). For users of these products, refer to the Mitsubishi Electric security advisory "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-001_en.pdf" and take the actions described there.

Mitigation: For users who need to continue using an affected version of GENESIS64 or ICONICS Suite and do not require communication with Mitsubishi Electric devices, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend not installing the Mitsubishi Electric FA Connector component during software installation, to avoid the risk of exploitation of this vulnerability. For existing sys…

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend restricting physical access to the PC with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend installing antivirus software in your computer with the affected product installed, to minimize the risk of exploiting this vulnerability.

Mitigation: For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions recommend preventing the user from clicking on web links in emails from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability.

Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.

News Coverage

No coverage found in monitored research blogs or news feeds.

CVEs Referenced in This Publication

CVECVSSAffected
CVE-2024-22106 8.8 High n/a n/a Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Deni…
CVE-2023-51776 7.8 High n/a n/a Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code.
CVE-2024-25086 7.8 High n/a n/a Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code.
CVE-2024-25088 7.8 High n/a n/a Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
CVE-2024-26314 7.8 High n/a n/a Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
CVE-2023-51777 5.5 Medium n/a n/a Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
CVE-2023-51778 5.5 Medium n/a n/a Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service …
CVE-2024-22102 5.5 Medium n/a n/a Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
CVE-2024-22104 5.5 Medium n/a n/a Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service …
CVE-2024-22105 5.5 Medium n/a n/a Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error.
CVE-2024-25087 5.5 Medium n/a n/a Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error.
CVE-2024-22103 4.4 Medium n/a n/a Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service …

Named by the advisory itself. Each CVE links to its tracked detail page.

Vendors Named in This Publication

No KEV-catalogued vendors are named in this publication.