Republished vendor advisory. This ICSA is a verbatim republication of Siemens ProductCERT SSA-301229 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA…
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Credit: Siemens ProductCERT; Trae Mazza (RMC Global)
From CISA's machine-readable CSAF 2.0 advisory (JSON).
| CVE | Weakness | CVSS v3 | Details |
|---|---|---|---|
| CVE-2025-32469 | CWE-602 Client-Side Enforcement of Server-Side Security | 9.9 Critical |
CVE-2025-32469 The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. Vendor fix: Update to V2.16.5 or later version ↗ Affected, fixed & timelineAffected:
|
| CVE-2025-33024 | CWE-602 Client-Side Enforcement of Server-Side Security | 9.9 Critical |
CVE-2025-33024 The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. Vendor fix: Update to V2.16.5 or later version ↗ Affected, fixed & timelineAffected:
|
| CVE-2025-33025 | CWE-602 Client-Side Enforcement of Server-Side Security | 9.9 Critical |
CVE-2025-33025 The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. Vendor fix: Update to V2.16.5 or later version ↗ Affected, fixed & timelineAffected:
|
| CVE-2025-40591 | CWE-602 Client-Side Enforcement of Server-Side Security | 7.7 High |
CVE-2025-40591 The 'Log Viewers' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute the 'tail' command with root privileges and disclose contents of all files in the filesystem. Vendor fix: Update to V2.16.5 or later version ↗ Affected, fixed & timelineAffected:
|
Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.
No coverage found in monitored research blogs or news feeds.
| CVE | CVSS | Affected |
|---|---|---|
| CVE-2025-32469 | 9.9 Critical | Siemens RUGGEDCOM ROX MX5000 A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX … |
| CVE-2025-33024 | 9.9 Critical | Siemens RUGGEDCOM ROX MX5000 A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX … |
| CVE-2025-33025 | 9.9 Critical | Siemens RUGGEDCOM ROX MX5000 A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX … |
| CVE-2025-40591 | 7.7 High | Siemens RUGGEDCOM ROX MX5000 A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX … |
Named by the advisory itself. Each CVE links to its tracked detail page.
Each vendor links to its Known Exploited Vulnerabilities catalog page. Only vendors that appear in the KEV catalog are listed, either because the publication cites one of their KEV entries or because it names them directly.