Republished vendor advisory. This ICSA is a verbatim republication of Siemens ProductCERT SSA-367714 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA…
General Recommendations: As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Credit: Siemens ProductCERT
From CISA's machine-readable CSAF 2.0 advisory (JSON).
| CVE | Weakness | CVSS v3 | Details |
|---|---|---|---|
| CVE-2022-31807 | CWE-347 Improper Verification of Cryptographic Signature | 6.2 Medium |
CVE-2022-31807 Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly". Mitigation: Enable TLS for communication between servers and affected devices; this mitigates the risk of on-path attackers that intercept and modify the firmware during transmission No fix planned: Currently no fix is planned Affected, fixed & timelineAffected:
|
Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.
No coverage found in monitored research blogs or news feeds.
| CVE | CVSS | Affected |
|---|---|---|
| CVE-2022-31807 | 6.2 Medium | Siemens Building X - Security Manager Edge Controller (ACC-AP) A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check … |
Named by the advisory itself. Each CVE links to its tracked detail page.