CyberzSOC

Publication detail
← Back to advisories & guidance

ICSA-25-266-03: Schneider Electric SESU ↗ source

September 23, 2025 CISA ICS Advisory

Summary

Schneider Electric is aware of a vulnerability in the Schneider Electric Software Update product (also referred to as “SESU”). The main purpose of the SESU software is to notify customers on the availability of hotfixes or new versions to download and install such updates. Failure to apply the fix provided below may risk attacker to write arbitrary data into protected locations, potentially leading to privilege escalation, arbitrary file corruption, exposure of application and system information or a persistent denial of service condition. CVE-2025-5296: CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder.

Advisory Details CISA ICS CSAF feed

Advisory ID
ICSA-25-266-03
Status
Final · version 2.0.0
Initial release
2025-08-12
Last revised
2025-09-09 (2 revisions)
Vendor
Schneider Electric
Critical infrastructure sectors
Chemical, Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health, Information Technology, Transportation Systems, Water and Wastewater Systems
Deployed
Worldwide
Vendor headquarters
France

Republished vendor advisory. This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-224-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory.…

General Security Recommendations: We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.

For More Information: This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp

About Schneider Electric: Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com

Credit: Schneider Electric CPCERT

Affected products (26)
  • SESU — <3.0.12, 3.0.12
  • BESS ANSI
  • Easergy MiCOM P30
  • Easergy MiCOM P40
  • Easergy Studio
  • EcoStruxure Automation Expert
  • Harmony XB5S Soft
  • eXLhoist Configuration Software
  • EcoStruxure Automation Device Maintenance
  • EcoStruxure Machine Expert
  • EcoStruxure Machine Expert Basic
  • EcoStruxure Automation Expert Motion
  • EcoStruxure Operator Terminal Expert
  • EcoStruxure Control Expert
  • EcoStruxure Process Expert
  • EcoStruxure Process Expert for AVEVA System Platform
  • EcoStruxure Architecture Builder
  • EcoStruxure Machine Expert HVAC
  • EcoStruxure Power Operations (EPO)
  • EcoStruxure Power Commission Desktop (EPC)
  • EcoStruxure Microgrid Operations Medium
  • EcoStruxure Microgrid Flex
  • PowerLogic P5
  • PowerLogic P7
  • ZelioSoft 2
  • SoMove
Revision history (2)
  • 2025-09-09 — v2.0.0: SESU as standalone added to known-affected and fixed.
  • 2025-08-12 — v1.0.0: Original Release

From CISA's machine-readable CSAF 2.0 advisory (JSON).

Vulnerabilities as Stated by the Advisory

CVEWeaknessCVSS v3Details
CVE-2025-5296 CWE-59 Improper Link Resolution Before File Access ('Link Following') 7.3 High CVE-2025-5296
CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder.

Vendor fix: Version 3.0.12 of SESU includes a fix for this vulnerability and is available for download here: https://www.seupdate.schneiderelectric.com/download/SystemConsistency/Soft wareUpdate/SESU_latest_version/SESU_latest _setup_sfx.exe Follow the installation inst… ↗

Mitigation: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: SESU Installation Directory (chosen by the customer at installation time) should not be accessible from the…

Affected, fixed & timeline

Affected:

  • SESU <3.0.12
  • CSAFPID-0028
  • CSAFPID-0029
  • CSAFPID-0030
  • CSAFPID-0031
  • CSAFPID-0032
  • CSAFPID-0033
  • CSAFPID-0034
  • CSAFPID-0035
  • CSAFPID-0036
  • CSAFPID-0037
  • CSAFPID-0038
  • CSAFPID-0039
  • CSAFPID-0040
  • CSAFPID-0041
  • … and 11 more

Fixed in:

  • SESU 3.0.12
  • CSAFPID-0053
  • CSAFPID-0054
  • CSAFPID-0055
  • CSAFPID-0056
  • CSAFPID-0057
  • CSAFPID-0058
  • CSAFPID-0059
  • CSAFPID-0060
  • CSAFPID-0061
  • CSAFPID-0062
  • CSAFPID-0063
  • CSAFPID-0064
  • CSAFPID-0065
  • CSAFPID-0066

Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.

News Coverage

No coverage found in monitored research blogs or news feeds.

CVEs Referenced in This Publication

CVECVSSAffected
CVE-2025-5296 7.0 High Schneider Electric SESU CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protect…

Named by the advisory itself. Each CVE links to its tracked detail page.

Vendors Named in This Publication

Each vendor links to its Known Exploited Vulnerabilities catalog page. Only vendors that appear in the KEV catalog are listed, either because the publication cites one of their KEV entries or because it names them directly.