CyberzSOC

Publication detail
← Back to advisories & guidance

ICSA-25-226-20: Siemens RUGGEDCOM ROX II ↗ source

August 14, 2025 CISA ICS Advisory

Summary

RUGGEDCOM ROX II devices do not properly limit access through their Built-In-Self-Test (BIST) mode. This could allow a local attacker to bypass authentication and access a root shell on the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. CVE-2025-40761: Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.

Advisory Details CISA ICS CSAF feed

Advisory ID
ICSA-25-226-20
Status
Final · version 1
Initial release
2025-08-12
Last revised
2025-08-12
Vendor
Siemens
Critical infrastructure sectors
Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities
Deployed
Worldwide
Vendor headquarters
Germany

Republished vendor advisory. This ICSA is a verbatim republication of Siemens ProductCERT SSA-094954 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA…

General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories

Credit: Siemens ProductCERT

Affected products (11)
  • RUGGEDCOM ROX MX5000 — all versions
  • RUGGEDCOM ROX MX5000RE — all versions
  • RUGGEDCOM ROX RX1400 — all versions
  • RUGGEDCOM ROX RX1500 — all versions
  • RUGGEDCOM ROX RX1501 — all versions
  • RUGGEDCOM ROX RX1510 — all versions
  • RUGGEDCOM ROX RX1511 — all versions
  • RUGGEDCOM ROX RX1512 — all versions
  • RUGGEDCOM ROX RX1524 — all versions
  • RUGGEDCOM ROX RX1536 — all versions
  • RUGGEDCOM ROX RX5000 — all versions

From CISA's machine-readable CSAF 2.0 advisory (JSON).

Vulnerabilities as Stated by the Advisory

CVEWeaknessCVSS v3Details
CVE-2025-40761 CWE-288 Authentication Bypass Using an Alternate Path or Channel 7.6 High CVE-2025-40761
Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.

Mitigation: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. See https://support.industry.siemens.com/cs/document/109983826/ Sec. 5.9.3 for more details

Mitigation: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. See https://support.industry.siemens.com/cs/document/109983829/ Sec. 5.9.3 for more details

Mitigation: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. See https://support.industry.siemens.com/cs/document/109983832/ Sec. 5.9.3 for more details

Affected, fixed & timeline

Affected:

  • RUGGEDCOM ROX MX5000 all versions
  • RUGGEDCOM ROX MX5000RE all versions
  • RUGGEDCOM ROX RX1400 all versions
  • RUGGEDCOM ROX RX1500 all versions
  • RUGGEDCOM ROX RX1501 all versions
  • RUGGEDCOM ROX RX1510 all versions
  • RUGGEDCOM ROX RX1511 all versions
  • RUGGEDCOM ROX RX1512 all versions
  • RUGGEDCOM ROX RX1524 all versions
  • RUGGEDCOM ROX RX1536 all versions
  • RUGGEDCOM ROX RX5000 all versions

No fix available: Currently no fix is available

Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.

News Coverage

No coverage found in monitored research blogs or news feeds.

CVEs Referenced in This Publication

CVECVSSAffected
CVE-2025-40761 7.6 High Siemens RUGGEDCOM ROX MX5000 A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions…

Named by the advisory itself. Each CVE links to its tracked detail page.

Vendors Named in This Publication

Each vendor links to its Known Exploited Vulnerabilities catalog page. Only vendors that appear in the KEV catalog are listed, either because the publication cites one of their KEV entries or because it names them directly.