Republished vendor advisory. This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
General Recommendations: As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Credit: Airbus Security
From CISA's machine-readable CSAF 2.0 advisory (JSON).
| CVE | Weakness | CVSS v3 | Details |
|---|---|---|---|
| CVE-2025-27494 | CWE-20 Improper Input Validation | 9.1 Critical |
CVE-2025-27494 Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges. Mitigation: Set an individual strong password for the administrator account ("SIEMENS") Vendor fix: Update to V6.4.9 or later version Affected, fixed & timelineAffected:
|
| CVE-2025-27493 | CWE-20 Improper Input Validation | 8.2 High |
CVE-2025-27493 Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges. Mitigation: Set an individual strong password for the administrator account ("SIEMENS") Vendor fix: Update to V6.4.9 or later version Affected, fixed & timelineAffected:
|
| CVE-2024-52285 | CWE-306 Missing Authentication for Critical Function | 5.3 Medium |
CVE-2024-52285 Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data. Vendor fix: Update to V6.4.8 or later version Affected, fixed & timelineAffected:
|
Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.
No coverage found in monitored research blogs or news feeds.
| CVE | CVSS | Affected |
|---|---|---|
| CVE-2025-27494 | 9.1 Critical | Siemens SiPass integrated AC5102 (ACC-G2) A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). A… |
| CVE-2025-27493 | 8.2 High | Siemens SiPass integrated AC5102 (ACC-G2) A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). A… |
| CVE-2024-52285 | 5.3 Medium | Siemens SiPass integrated AC5102 (ACC-G2) A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). A… |
Named by the advisory itself. Each CVE links to its tracked detail page.
Each vendor links to its Known Exploited Vulnerabilities catalog page. Only vendors that appear in the KEV catalog are listed, either because the publication cites one of their KEV entries or because it names them directly.