| CVE | Weakness | CVSS v3 | Details |
|---|---|---|---|
| CVE-2024-2425 | CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') | 7.5 High |
A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it. Mitigation: Rockwell Automation does not currently have a fix for these vulnerabilities. Users of the affected software are encouraged to apply risk mitigations and security best practices, where possible. Mitigation: Implement network segmentation confirming the device is on an isolated network. Mitigation: Disable the web server, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later. Affected, fixed & timelineAffected:
Mitigation: Security Best Practices Mitigation: For more information, visit Rockwell Automation's security advisory page. |
| CVE-2024-2426 | CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') | 7.5 High |
A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it. Mitigation: Rockwell Automation does not currently have a fix for these vulnerabilities. Users of the affected software are encouraged to apply risk mitigations and security best practices, where possible. Mitigation: Implement network segmentation confirming the device is on an isolated network. Mitigation: Disable the web server, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later. Affected, fixed & timelineAffected:
Mitigation: Security Best Practices Mitigation: For more information, visit Rockwell Automation's security advisory page. |
| CVE-2024-2427 | CWE-400 Uncontrolled Resource Consumption | 7.5 High |
A denial-of-service vulnerability exists in the PowerFlex 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover. Mitigation: Rockwell Automation does not currently have a fix for these vulnerabilities. Users of the affected software are encouraged to apply risk mitigations and security best practices, where possible. Mitigation: Implement network segmentation confirming the device is on an isolated network. Mitigation: Disable the web server, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later. Affected, fixed & timelineAffected:
Mitigation: Security Best Practices Mitigation: For more information, visit Rockwell Automation's security advisory page. |
Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.
No coverage found in monitored research blogs or news feeds.
| CVE | CVSS | Affected |
|---|---|---|
| CVE-2024-2425 | 7.5 High | Rockwell Automation PowerFlex® 527 A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, the… |
| CVE-2024-2426 | 7.5 High | Rockwell Automation PowerFlex® 527 A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a d… |
| CVE-2024-2427 | 7.5 High | Rockwell Automation PowerFlex® 527 A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple dat… |
Named by the advisory itself. Each CVE links to its tracked detail page.
Each vendor links to its Known Exploited Vulnerabilities catalog page. Only vendors that appear in the KEV catalog are listed, either because the publication cites one of their KEV entries or because it names them directly.