Republished vendor advisory. This CISA CSAF advisory was converted from Hitachi Energy PSIRT's CSAF advisory.
Support: For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.
General Mitigation Factors: Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. For instance, Open Database Connectivity (ODBC) protocol that is used for device configuration should be limited within the substation only. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.
Credit: Robert Erbes (U.S. Department of Energy CyTRICS)
From CISA's machine-readable CSAF 2.0 advisory (JSON).
| CVE | Weakness | CVSS v3 | Details |
|---|---|---|---|
| CVE-2021-35534 | CWE-274 Improper Handling of Insufficient Privileges | 7.2 High |
A vulnerability exists in the database schema inside the product. An attacker could exploit the vulnerability by first gaining access to credentials of any account or to have access to a session ticket issued for an account. After that, via the configuration tool that accesses the proprietary Open Database Connectivity (ODBC) protocol (TCP 2102), the database table can be manipulated for privilege escalation which then allowed unauthorized modification or to permanently disabling of the device. Vendor fix: Update to Relion 670/650/SAM600-IO series version 2.2.1.8 Vendor fix: Update to Relion 670 series version 2.2.2.5 Vendor fix: Update to Relion 670 series version 2.2.3.5 Affected, fixed & timelineAffected:
Vendor fix: Update to Relion 670/650 series version 2.2.4.3 Vendor fix: Update to Relion 670/650/SAM600-IO series version 2.2.5.2 Vendor fix: Update to Relion 670/650 series version 2.1.0.5 Vendor fix: Update to Relion 670/650 series version 2.0.0.14 Vendor fix: Update to Relion 650 series version 1.3.0.8 Mitigation: Refer to the General Mitigation Factors/Workaround Section for the current mitigation strategy. Mitigation: Refer to the Mitigation Factors/Workaround Section for the current mitigation strategy or upgrade to Relion 650 series version 1.3. |
Scores and weakness types are as CISA or the republishing vendor stated them in this advisory; the linked CVE pages carry the independently enriched CVSS and SSVC assessments.
No coverage found in monitored research blogs or news feeds.
| CVE | CVSS | Affected |
|---|---|---|
| CVE-2021-35534 | 7.2 High | Hitachi Energy Relion 670 Series Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC… |